扫描手机二维码

欢迎您的访问
您是第 位访客

开通时间:..

最后更新时间:..

  • 张海峰 ( 副研究员 ) 赞

    的个人主页 http://shi.buaa.edu.cn/zhanghaifeng/zh_CN/index.htm

  •   副研究员   博士生导师   硕士生导师
论文 当前位置: 张海峰 >> 论文
Near-zero magnetic field disturbance suppression method based on adaptive filtering and quasi-proportional resonance control
点击次数:
影响因子:2.6
DOI码:10.1088/1402-4896/ad74a7
所属单位:仪器科学与光电工程学院
教研室:大科学装置研究院
发表刊物:Physica Scripta
摘要:Abstract The cardiac magnetic field used for magnetocardiographic (MCG) imaging must be detected in a stable near-zero magnetic field environment. In the hospital environment, there are mainly two kinds of magnetic field disturbances that affect the signal-to-noise ratio of cardiac magnetic field detection. One is the magnetic field disturbance with high power spectral density at a specific frequency, and the other is the random magnetic field disturbance with low frequency. To suppress magnetic field disturbances, this paper proposed a near-zero magnetic field disturbance suppression method t
合写作者:Haifeng Zhang, Pengtao Tian, Xiuqi Zhao, Shiqiang Zheng
第一作者:Haoting Wu
论文类型:期刊论文
学科门类:工学
一级学科:仪器科学与技术
文献类型:期刊
卷号:99
期号:10
页面范围:105249
ISSN号:0031-8949, 1402-4896
是否译文:否
发表时间:2024-10-01
版权所有 2014-2022 北京航空航天大学  京ICP备05004617-3  文保网安备案号1101080018
地址:北京市海淀区学院路37号  邮编:100191  电话:82317114