High-precision magnetic field disturbance suppression method based on delay and interference compensation for cardiac magnetic signals
点击次数:
影响因子:6.1
DOI码:10.1016/j.measurement.2026.120793
所属单位:仪器科学与光电工程学院
教研室:大科学装置研究院
发表刊物:Measurement
关键字:Active magnetic compensation (AMC); Delay compensation; Optical pump magnetometer (OPM); Smith predictor and dual-estimation disturbance observer (SDEDO)
摘要:The high-precision measurement for the cardiac magnetic field signal is highly sensitive to magnetic fluctuations within a magnetic shielding device. The active magnetic compensation (AMC) is an effective method for suppressing these disturbances. Due to the measurement delay of the feedback sensor, the suppression of magnetic field fluctuations is insufficient. A high-precision magnetic field disturbance suppression method based on delay and interference compensation is proposed in this paper. This method employs a time delay compensation system based on the Smith predictor (SP) to address th
合写作者:Haitao Li, Haifeng Zhang, Haoan Wang
第一作者:Xuechun Wang
论文类型:期刊论文
学科门类:工学
一级学科:仪器科学与技术
文献类型:期刊
卷号:270
页面范围:120793
ISSN号:0263-2241
是否译文:否
发表时间:2026-04-01