Impact Factor:3.2
DOI number:10.1088/1361-6463/ae6dd3
Affiliation of Author(s):仪器科学与光电工程学院
Teaching and Research Group:大科学装置研究院
Journal:Journal of Physics D: Applied Physics
Abstract:Abstract Magnetically shielded rooms (MSR) composed of high-permeability materials provided a near-zero magnetic environment for ultra-weak field measurements, such as biomagnetic cardiography and encephalography. To maximise material performance, a demagnetization current is applied to increase the effective permeability, thereby enhancing the shielding performance of the MSR. However, conventional open-loop demagnetization system is susceptible to disturbances that distort the current waveform and degrade the demagnetization effect. To improve disturbance suppression, this paper proposes a c
Co-author:Minxia Shi, Haifeng Zhang, Jianzhi Yang, Zhihui Hong, Xinyi Yu, Shiqiang Zheng
First Author:Di Zhang
Indexed by:Journal paper
Discipline:工学
First-Level Discipline:Instrumentation Science and Technology
Document Type:J
Volume:59
Issue:21
Page Number:215002
ISSN No.:0022-3727, 1361-6463
Translation or Not:no
Date of Publication:2026-05-29