Impact Factor:2.3
DOI number:10.1049/iet-pel.2019.0488
Affiliation of Author(s):仪器科学与光电工程学院
Teaching and Research Group:大科学装置研究院
Journal:IET Power Electronics
Key Words:permanent magnet synchronous motor; PMSM; sliding mode observer; position control; angular velocity control; composite speed controller; electric potential; fixed frequency extraction filter; harmonic position errors; high energy efficiency; high power density; high precision speed control; high-order harmonics; high-performance control method; ideal drive; installation space limitation; machine control; magnetically suspended turbo-molecular pump; mechanical position sensors; MSTMP motor; obser
Abstract:Permanent magnet synchronous motor (PMSM) is the ideal drive for the magnetically suspended turbo-molecular pump (MSTMP) for its high power density, reliable operation and high energy efficiency. Rotor position information is necessary to drive the PMSM. However, because of the installation space limitation and reliability requirement, position sensorless control technology without mechanical position sensors is more attractive. In this study, a sliding mode observer is adopted to estimate the back electromotive force (EMF) that contains the position information. Since the high-order harmonics
Co-author:Gang Liu
First Author:Haifeng Zhang
Indexed by:Journal paper
Discipline:工学
First-Level Discipline:Instrumentation Science and Technology
Document Type:J
Volume:13
Issue:2
Page Number:266-274
ISSN No.:1755-4543
Translation or Not:no
Date of Publication:2020-01-01